Usi Electric Smoke Detector S-1810 Manual

USI 1204 Smoke Detector, Ionization Sensor, 120VAC, Wire-In, White Smoke Detector, Ionization Sensor, 120V AC. USI Installation Manual - USI Cut Sheet - USI. Gulliver mod 1.7.10.

Ionization smoke & fire alarm, carbon monoxide alarm & natural gas alarm.
Hide thumbs
THANK YOU for purchasing this combination alarm. This manual includes important information
regarding where to install the alarm, how to operate, maintenance, testing and product features. It
also includes tips and information which could help protect you and your family.
Alarm Limitations and Functions ............................. 2
What You Should Know About CO ............................ 3
What You Should Know About Natural Gas ..................... 3
Basic Safety Information ................................... 5
Recommended Location of Alarms ......................... 5, 6
Where Alarm Should Not Be Installed ......................... 6
Installation Instructions .................................... 7
Electrical Shock Hazard .................................... 7
Locking / Tamper Feature .................................. 7
Wiring Instructions, Interconnection & Compatibility .......... 7, 8, 9
Operation, Testing & Maintenance ............................ 9
What To Do If The Alarm Sounds ............................ 10
CO & Smoke Alarm Silence Feature .......................... 11
Testing & Maintenance .................................... 12
Battery Backup Replacement ............................... 13
Smoke, CO & Natural Gas Alarm Limitations .................. 13
Operational Summary ................................. 16, 17
Warranty ........................................ Back Cover
IONIZATION SMOKE & FIRE ALARM,
NATURAL GAS ALARM
MODEL MICN102, MICN102L
CARBON MONOXIDE ALARM &
120VAC 60 Hz 100 mA Max.

Table of Contents:

Alarm Originating Feature & Reset ............... 10

Advertisement

Also See for Universal Security Instruments MICN109

Universal Security Instruments MICN102 User Manual17 pages

Related Manuals for Universal Security Instruments MICN109

Summary of Contents for Universal Security Instruments MICN109

  • Page 1: Table Of Contents

    MODEL MICN109, MICN109L IONIZATION SMOKE & FIRE ALARM, CARBON MONOXIDE ALARM & NATURAL GAS ALARM 120VAC 60 Hz 100 mA Max. MODEL MICN102, MICN102L IONIZATION SMOKE & FIRE ALARM, CARBON MONOXIDE ALARM & SECURITY INSTRUMENTS, INC. NATURAL GAS ALARM 120VAC 60 Hz 100 mA Max.
  • Page 2: Alarm Limitations And Functions

    ALARM LIMITATIONS AND FUNCTIONS This Combination Smoke/Carbon Monoxide (CO) and Natural Gas alarm requires constant 120  VAC power to operate properly. ® There are three basic smoke alarm types: IoPhic , Ionization and Photoelectric.  ® ® is an ionization alarm containing patented Universal Smoke Sensing Technology .
  • Page 3: What You Should Know About Co

    WHAT YOU SHOULD KNOW ABOUT CO Carbon monoxide (CO) is an insidious poison. It is a colorless, odorless, tasteless gas. It is a cumulative poison. Even low levels of CO have been shown to cause brain and other vital organ damage in unborn infants with no effect on the mother.
  • Page 4 • An alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms. Where bedrooms are separated and audibility of the alarm to occupants within the bedroom area could be seriously impaired, more than one alarm could be needed. •..
  • Page 5: Basic Safety Information

    In general, install combination Smoke, CO and Gas Alarms: • WHERE YOU CAN HEAR THE ALARM FROM ALL SLEEPING AREAS. • In or near bedrooms and living areas or wherever you suspect a smoke, natural gas or CO exposure is likely. •..
  • Page 6: Where Alarm Should Not Be Installed

    NOTE: For any location, make sure no door or other obstruction could prevent the smoke, carbon monoxide or gas from reaching the alarm. WHERE THIS ALARM SHOULD NOT BE INSTALLED To avoid causing damage to the unit, to provide optimum protection, and to prevent unnecessary alarms.
  • Page 7: Installation Instructions

    INSTALLATION INSTRUCTIONS: CAUTION!! READ CAREFULLY. Installation of this alarm must conform to the electrical codes in your area; Article 760 of the National Electrical Code, NFPA 72, 101; SBC (SBCCI); UBC (ICBO); NBC (BOCA): OTFDC (CABO), and any other local or building codes that may apply. Wiring and installation must be performed by a licensed electrician.
  • Page 8: Wiring Instructions, Interconnection & Compatibility

    Natural gas detection is only present in models MDSCN111, MSDCN103, MICN109, MICN102, MCN108 and MCN105; therefore, a natural gas alarm will NOT trigger the alarm of non-natural gas sensing models within an interconnected system.
  • Page 9: Operation, Testing & Maintenance

    120 VAC 60Hz 100mA Max. The yellow wire is used only for multiple station operations with USI ELECTRIC or UNIVERSAL Model alarms only. Connecting this yellow wire to any other circuits may result in damage and alarm malfunction. When alarms are interconnected, all alarms must be powered from a single AC branch circuit.
  • Page 10: Quick Find Alarm Originating Feature & Reset

    NUISANCE ALARM: If the horn signals and the red or blue LED’s blink on for no apparent reason and no obvious hazard is present, please verify that the alarm is mounted in the correct location. Reset the alarm as instructed in the Operational Summary. SMOKE ALARM LATCHING LED INDICATOR: The alarm had previously detected smoke and had alarmed.
  • Page 11: Co & Smoke Alarm Silence Feature

    After following steps 1-3, if your alarm reactivates within a 24 hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances and inspect for proper operation of this equipment. If problems are identified during this inspection, have the equipment serviced immediately.
  • Page 12: Testing & Maintenance

    END-OF-SERVICE LIFE NOTIFICATION: A majority of home fire deaths are a result of no smoke alarms or no working smoke alarms. In addition to the 'replace by date' stamped on the back of your alarm, your alarm contains a unique audible end-of-service life notification feature. When it is time to replace your alarm, which is after approx.
  • Page 13: Battery Backup Replacement

    BACKUP BATTERY REPLACEMENT Disconnect AC power before changing battery. Shock hazard exists if AC power is miswired. The alarm uses a 9 Volt battery. The battery should last for at least one year under normal operating conditions. The alarm has a low battery indicator, an audible beep or chirp. It will operate at approx.
  • Page 14 • Simultaneous operation of several fuel-burning appliances competing for limited internal air. • Vent pipe connections vibrating loose from clothes dryers, furnaces or water heaters. • Obstructions in or unconventional vent pipe designs which can amplify the above situations. 2. Extended operation of unvented fuel-burning devices (ranges, ovens, fireplaces). 3.
  • Page 15 NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED INFORMATION For your information, the National Fire Alarm Code, NFPA 72, reads as follows: '11.5.1 *Required Detection - Where required by applicable laws, codes, or standards for a specific type of occupancy, approved single and multiple-station smoke alarms shall be installed as follows: (1) *In all sleeping rooms and guest rooms (2) *Outside of each separate dwelling unit sleeping area, within 6.4 m (21 ft) of any door to a sleeping room, the distance measured along a path of travel..
  • Page 16: Operational Summary

    OPERATIONAL SUMMARY AUDIBLE & VISUAL SIGNALS CONDITION / RECOMMENDATION SMOKE POWER HORN GREEN LED RED LED BLUE LED RED LED Silent On and Blinks Condition: AC power is present. DC power is present. Off approx Recommendation: None every 20 seconds Silent Off and Blinks Condition: Alarm is powered by battery backup.
  • Page 17 5 interconnected system consisting of any of these models: 5304, seconds seconds every 5 seconds until MI106, MDS107, MCN108, MICN109, MDSCN111 and MP117, until reset seconds reset it may be difficult to determine which alarm initiated the alarms until reset to sound.
  • Page 18: Warranty

    MODELS MICN 109, MICN 109L MODELS MICN102, MICN102L USI ELECTRIC, INC. / UNIVERSAL SECURITY INSTRUMENTS, INC. (“USI”) warrants your product to be free from defects in material and workmanship for a period of seven (7) years from the date of purchase. This warranty shall not apply to any batteries used in the product or to any damage which may be caused by such batteries.